12kW Water-Cooled Radiator – Industrial Cooling for Bitmain & Whatsminer Hydro ASIC Miners
SKU: 12KW-ASIC-HYDRO-RADIATOR-AUTO
- HashrateHydroCooling
- Power400.00 W
- CoinHydro
€649.87
(excl.VAT)Guaranteed Safe Checkout
![]()
Ships in 24h 5 left
Order confirmed within 24hShips from Ireland & LatviaNo customs in the EU
Tracked deliveryTo all 27 EU countries
Warranty & supportAfter-sales help
Card, bank, cryptoSecure checkout
Specifications: 12kW Water-Cooled Radiator – Industrial Cooling for Bitmain & Whatsminer Hydro ASIC Miners
Coin
Hydro
Consumption
Hashrate
Model12kW Water-Cooled Radiator
Noise Level40-70db
Sizes74x50x10
Fans15
Voltage100-220v
Warranty180days
Description for: 12kW Water-Cooled Radiator – Industrial Cooling for Bitmain & Whatsminer Hydro ASIC Miners
12kW Water-Cooled Radiator – Industrial Cooling for Bitmain & Whatsminer Hydro ASIC Miners
Engineered for High-Performance Heat Dissipation in Crypto Mining Environments
The 12kW Water-Cooled Radiator is a high-efficiency, industrial-grade cooling solution designed for hydro-cooled ASIC miners such as Bitmain Antminer Hydro and Whatsminer Hydro series. With a cooling capacity tailored for up to 12.5kW of heat output, this radiator ensures consistent thermal management, enhances miner longevity, and maintains optimal performance even under extreme mining loads.
Built with high-quality aluminum cold exhaust channels, advanced sealing, and a smart automated fan control system, the radiator is ideal for data centers and mining operations that prioritize noise reduction and cooling reliability.
Product Specifications
| Feature | Details |
|---|---|
| Product Name | 12kW Water-Cooled Radiator |
| Model | 12kW |
| Cooling Capacity | Suitable for up to 12.5kW of equipment |
| Material | High-grade aluminum cold exhaust system |
| Weight (with packaging) | 17 kg |
| Dimensions | 740 x 503 x 97 mm |
| Color | White |
| Sealing Performance | ≤ 0.2 MPa |
| Insulation Level | E-Class (up to 120°C) |
| Fan Count | 15 Fans |
| Fan Speed | 500–5600 RPM (Auto-adjusting) |
| Noise Level | Ultra-Low – Ideal for quiet mining setups |
Key Features
-
High Cooling Capacity – Designed for hydro miners producing up to 12.5kW of heat
-
Advanced Air-Water Heat Dissipation – Efficient aluminum cold exhaust channels deliver top-tier performance
-
Ultra-Low Noise Output – 15 silent fans with variable RPM keep the unit whisper quiet
-
Smart Fan Control – RPM adjusts automatically based on real-time cooling demand
-
Compatible with Top ASIC Miners – Built for Bitmain Hydro and Whatsminer Hydro models
Why Choose This 12kW Radiator?
-
Maximized Efficiency – Keeps ASICs at stable temps for consistent hashing power
-
Noise Reduction – Suitable for operations near residential zones or quiet server rooms
-
Plug-and-Play Integration – Easy to install in existing hydro setups
-
Long-Term Reliability – Built to withstand industrial use with high sealing and thermal protection
-
Scalable for Mining Farms – Supports parallel deployment across large hydro miner arrays
FAQs
Q: What miners is this radiator compatible with?
It's specifically designed for Bitmain Antminer Hydro and Whatsminer Hydro models.
Picture of assabled connections

Q: How loud is the unit in operation?
Despite its 15 fans, the automated speed control keeps it ultra-quiet even under high loads.
Q: Can it cool multiple miners?
It can support up to 2 miner connections, please be aware of ambient temperature and total power consumprion for cooling Radiator.
Q: Does it come pre-filled or assembled?
The radiator ships with installation-ready components; fluid and plumbing setup must be completed upon installation.
Optimize Your Hydro Mining Operation with 12kW of Silent, Efficient Cooling
Upgrade your hydro ASIC mining setup with this advanced 12kW water-cooled radiator—designed to keep your machines running cool, efficiently, and quietly around the clock.
This is Detailed Explanation of Temperature Parameters on radiator controls
1. Acceleration Temperature (L**)
Range: 10°C - 80°C
Function: When the detected temperature rises and exceeds this value, the fan output power will gradually increase as the temperature rises.
2. Full-Speed Temperature (H**)
Range: 20°C - 99°C
Function: When the temperature rises to or exceeds this value, the fan will always output 100% power and run at full speed.
3. Shutdown Temperature (C**)
Range: 0°C - maximum 70°C
Function: When this value is set to > 0, the low-temperature fan shutdown function is enabled, and the fan will stop rotating.
Example: If "L" is set to 20°C, the maximum value of "C" can be 18°C. When the temperature is lower than this value, all fans will not operate. (The difference between "C" and "L" must not be less than 2°C; otherwise, it will be automatically adjusted when saving.)
When in the shutdown state, the fan will restart and adjust speed with temperature when the temperature rises above the acceleration temperature.
4.If the shutdown temperature is set to 0, the low-temperature fan shutdown function will be invalid, and the fan will always output power, but it needs to be used with "P". ("P" must be adjusted to 6 or higher; the higher the value, the faster the rotation speed.)
5. Manual Speed Regulation ("P")
PWM output range: 0 - 99
The full-speed temperature H, 40 is the temperature.
It's 40 degrees Celsius.
When the temperature rises to or exceeds this temperature, the fan will always output 100% and run at full speed.
When H40 is displayed, the fan is running at full speed.
You set the full speed at 40 degrees Celsius. If you set H30, the fan will run at full speed when the water temperature reaches 30 degrees Celsius.
Warranty